386-322-7390
TM
TM
Find A U.S. Dealer
Click Link Below
(Opens A Pop-Up Window
To Enter Your Zip Code)
Downloaded Data Display: Data downloaded from the WEGO™ is displayed on a chart recorder type screen.
You Can Select Two Parameters For Display:
- Trace 1 - Displayed in red with its Y axis legends on the left side of the chart.
- Trace 2 - Displayed in green with its Y axis legends on the right side of the chart.
- X Axis - This is always elapsed time.
You can zoom in, zoom out, or zoom all (displays entire data file).
At the maximum zoom in level, approximately 100 data samples will be displayed on the chart.
You can use the scroll bar to move the chart display window in terms of elapsed time.
Fuel Type Input: WEGO™ units can be programmed to display Lambda or correct AFR values for any hydrocarbon fuel with a known stoichiometric ratio.
Regardless of the units displayed on the WEGO™, data is logged internally in Lambda units and can be rescaled in the software for any fuel type.
Please refer to the software instructions for details.
Click Image For Larger View Of The WEGO™ Single Channel Data Logging Screen →
WEGO™ Real Time Single Channel
Data Display
WEGO™ Data Logging Chart Screen
WEGO™ Analog Input Scaling Screen
AFR Data Analysis: AFR (air/fuel ratio) table display is only possible when both engine RPM and correctly scaled throttle position sensor (TPS) data has been logged from a fuel injected vehicle.
The table format is intended to match the RPM rows and TPS columns used by many industry standard engine mapping systems. The image figure to the right shows logged AFR data.
You can also display and print out the required fuel correction (in percent) based on the AFR target value you select.
You can add data from an unlimited number of files that you previously saved.
The data will be analyzed and incorporated into the table.
Cells that vary more than ±0.5 AFR from the command value are shaded blue for rich or red for lean.
Click Image For Larger View Of WEGO™
Single Channel Analog Input Scaling Screen
Click Below To View & Download WEGO™ Single Channel Logging Software Instructions
WEGO™ Single Channel
AFR Fuel Correction Display Screen
Analog Input Scaling: Our WEGO™ units allow you to also setup the scaling and units display for the 0-5V analog input. Selections are available for standard Delphi/GM 1 bar, 2 bar, and 3 bar manifold pressure (MAP) sensors. Most GM vehicles and all Harley-Davidson® motorcycles with Twin-Cam 88® engines use Delphi 1 bar type MAP sensors. Delphi/GM 2 bar and 3 bar MAP sensors are often used with aftermarket engine controls for turbo/supercharger applications. For other sensors, you can enter the minimum and maximum input voltages and corresponding scaled values displayed on the chart along with the desired chart legend.
ADD LINKS TO WEGO USERS IMAGES - DYI SNIFFER PRODUCTS AND OTHER THRID PARTY DISPLAYS AVAILABLE
(VERIFY ALL LINKS AND RELATIONSHIPS ARE STILL VALID TO PROMOTE - CONSULT ALLEN & HECTOR)
WEGO™ III vs. WEGO™ IV
What's The Difference?
WEGO™ III Series Are Stand-Alone Units With Built-In Data Logging - Intended For Harsh Environments
WEGO™ IV Series Are Stand-Alone Units
With Built-In Data Logging - Intended For Automotive Under-Dash Or Dyno Environments
Computer Requirements: The WEGO™ Data Logging software is compatible with PC computers using Microsoft® Windows® XP, Microsoft® Windows Vista®, Microsoft® Windows® 7, Microsoft® Windows® 8 and Microsoft® Windows® 10 OS Systems. Daytona Sensors™ Product Software Programs are NOT COMPATIBLE with any type of Mac® computer, iPad® or any other types or brands of tablet, smart phones or mobile devices. We no longer support older Microsoft® Windows® versions. Minimum PC requirement is a 300 MHz Pentium with super VGA display (SVGA with 1024 x 768 pixel resolution). WEGO™ units connect to the PC by means of a USB interface. A USB cable is supplied with the unit. The PC must have a free USB port. If you have an older PC without USB capability, you cannot use the WEGO™. For more detailed product information, we suggest that you download the WEGO™ software and WEGO™ instructions. Each software download includes a sample file with actual data.
Click Image For Larger View Of WEGO™
Single Channel Fuel Type Selection Screen
About The WEGO™ Display: The location of the decimal point on the WEGO™ LED display is set during manufacturing and cannot be changed. Standard WEGO™ units display AFR values with XX.X number format, such as AFR values from 10.3-19.5 for gasoline or 4.5-8.6 for methanol. Special WEGO™ units are available for Lambda display with X.XX number format (i.e. Lambda values from 0.70-1.33).
Click Image For Full Screen View Of WEGO™
Single Channel AFR Data Display Screen
The Software Basics: Daytona Sensors™ WEGO™ III and WEGO™ IV units feature data logging and include a built-in USB interface for easy connection to most modern laptop PCs. This data logging capability greatly facilitates engine tuning and diagnosis of drivability issues. WEGO™ units start logging data once the sensors have warmed up (typically 15 seconds). When the engine is running, you can display real time data on an instrument panel type layout with a round tach gauge and bar graph type gauges for most other parameters. Diagnostic codes are displayed in an additional window.
The Single Channel WEGO™ units store the last 8000 samples in non-volatile memory. This allows storage ranging from 13 minutes at 10 samples/second to over 2 hours at 1 sample/second. You can use our software to view data in real time or download and display data on a chart recorder type screen. Available data includes Air/Fuel Ratio (AFR), RPM, and a 0-5V analog input. The RPM input can be connected to a tachometer signal or directly driven from an ignition coil. RPM data is correctly scaled and displayed for 1-12 cylinder engines.
Special WEGO™ Technical Notes: For Suzuki® Hayabusa Applications and Dynojet® Dyno Users, we have special WEGO™ technical set-up information for you. Please click the appropriate link below for your application:
Click Image For Full Screen View Of WEGO™
Single Channel Data Logging Chart Screen
Subscribe To Our Daytona Sensors™ eNewsletter
Click Image For Full Screen View Of WEGO™
Single Channel AFR Fuel Correction Screen
WEGO™ Fuel Type Selection Screen
Click Image For Full Screen View Of WEGO™
Dual Channel AFR Data Display Screen
Correcting Your Engine Mapping Software: You can use two approaches to make the required corrections in the your engine mapping software.
If you have Microsoft Office® with Excel®, you can directly copy and paste data from the WEGO™ software to an Excel® spreadsheet and then copy and paste from the Excel® spreadsheet into the engine mapping software.
In the WEGO™ software, you can select a range of cells with the mouse and right click to bring up a copy menu. You can also left click on the upper left legend cell to select the entire table and then right click to bring up the copy menu.
For more details on using Excel® , including sample spreadsheets, please visit the WEGO™ Tech Tips section on our website (**** SCOTT NEEDS TO INSERT LINK WHEN READY*****).
Alternately, you can manually enter the required corrections in your engine mapping software by referring to the printed fuel percent correction table and marking off cells as you edit them.
For more details, please feel free to download and read our WEGO™ software instructions. Remember, you can 'Test-Drive' our WEGO™ software as well. Just click either of the links below.
WEGO™ Single Channel
AFR Data Display Screen